Interior decoration electrical and pipe acceptance rules
Decoration experience Hydropower renovation Socket switch residential TV decoration decoration design decoration living room bathroom design bathroom waterproof overall bathroom bathroom door Biological Microscope,Monocular Biological Microscope,Student Medical Lab Microscope,Economical Biological Microscope Ningbo Huaguang Precision Instrument Co., Ltd. , https://www.hgopt.com
First, do you have any questions about all switches, sockets, and mains? The location of various circuits, closed-circuit televisions, telephone sockets, etc. should also be carefully understood. 30% of fires are caused by electrical accidents. This is related to the setting of electrical circuits. In order to ensure the safety and convenience of using electricity, the State has issued the "Code for the Design of Housing", which stipulates that the number of residential circuits in each set should not be less than five. Increasing the loop can ensure the service life of the wire and reduce the occurrence of short-circuit fire accidents. Details are as follows:
One indoor distribution box
1. Is the circuit inside the box marked?
2. Is there a wire docking phenomenon inside the box?
3. Is the grounding wire in place?
4. Whether multiple strands are soldered
5 whether the wire enters the wiring pile part is exposed
6, whether the pipeline into the box has a hat
7ã€Whether the inside of the box is clean or not, switch, socket
1, whether the height is the same, whether the control is orderly, and the direction is the same
2, the distance between the switch and the edge of the door is reasonable (15-20CM)
3, the socket phase is correct, whether there are multiple wires to connect a pile head phenomenon
4ã€Whether the wire reserve length is reasonable
5, insulation is good (lighting 0.5MΩ power 1MΩ)
6, whether the distance between strong and weak electricity is standardized
7ã€Whether the bathroom is waterproof (Proposed children use protective socket)
Third, lamps
1, the installation is solid
2. Is it centered?
3ã€Whether the height is lower than 2.2 meters with grounding (mahjong lights, toilets)
Fourth, whether the equal potential is set five, air conditioning socket
1, location, height is reasonable
2, is the correct diameter
3, the panel is matched with the air conditioning 16A
4ã€Whether the condensation outlet pipe is reasonable 6. Kitchen room
1, whether the basin fell into the water level is reasonable (in the future decoration)
2, whether to set the floor drain
3, there is no rain, pollution, waste use the same phenomenon VII, bathroom
1, check the height of the mouth is reasonable
2, whether the accessories with a check door
3, whether the slope of the horizontal pipe is reasonable
4, whether the bracket is in place
5, whether the riser is equipped with expansion joints
6, whether to set the mop pool
7. Are floor boards and walls worn? Are there any exposed pipes in the living room and living room? Whether there is heating backwater or other pipelines to pass through, because there are more pipelines across the room, it will cause decoration difficulties, will also cause visual obstacles, affect the overall sense.