Specification and weight of low carbon steel wire and electrogalvanized steel wire

Specification and weight of low carbon steel wire and electrogalvanized steel wire
Specification and weight of low carbon steel wire and electrogalvanized steel wire
Model Nominal diameter (mm) Theoretical weight Weight per bundle Model Nominal diameter (mm) Theoretical weight Weight per bundle
Low carbon steel wire Electroplated, hot-dip galvanized steel wire (kg/100m) (kg) Low carbon steel wire Electroplated, hot-dip galvanized steel wire (kg/100m) (kg)
0.16 0.0158 19 1.00 1.00 0.617 25
0.18 0.0200 18 1.20 1.20 0.888 25.50
33 0.20 0.20 0.0247 [10], [5] 17 1.40 1.40 1.21 25.50
32 0.22 0.22 0.0298 (10) 16 1.60 1.60 2.58 25.50
31 0.25 0.25 0.0385 [10], [5] 15 1.80 1.80 2.00 25.50
30 0.28 0.28 0.0483 (10) 14 2.00 2.00 2.47 25.50
29 0.30 0.30 0.0555 (10), [5] 13 2.20 2.20 2.98 50
28 0.35 0.35 0.0755 15,(10),[5] 12 2.50 2.50 3.85 50
27 0.40 0.40 0.0987 15,(10),[5] 11 2.80 2.80 4.82 50
26 0.45 0.45 0.125 15,(10),[5] 10 3.0 3.00 5.55 50
25 0.50 0.50 0.154 15,(10),[5] 9 3.5 3.50 7.55 50
twenty four 0.55 0.55 0.187 25 8 4.0 4.00 9.87 50
twenty three 0.60 0.60 0.222 25 7 4.5 4.50 12.50 50
twenty two 0.70 0.70 0.302 25 6 5.0 5.00 15.40 50
twenty one 0.80 0.80 0.395 25 5 5.50 5.50 18.70 50
20 0.90 0.90 0.499 25 4 6.0 6.00 22.20 50
Note (1) The specification of low carbon steel wire is 0.16~10mm. This table only lists common specifications.
(2) The theoretical weight value does not count the weight of the zinc layer;
(3) There are no 0.22, 0.280, and 0.55 specifications in the nominal diameter of hot-dip galvanizing. The figures in brackets ( ) and [ ] are the weight of each bundle of electro-galvanized and hot-dip galvanized, respectively.
The others are the same as the low carbon steel wire.
Http://news.chinawj.com.cn Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn

Others Mass Flow Meter

Sealand is a trustworthy supplier of Mass Flow Transmitter, Mass Flow Sensor, Mass Flow Metre, Coriolis Metre, ATEX, IECEx & CE approved.

Sealand Mass flow meter measures the mass based on Coriolis effort. The operating principle involves inducing a vibration of the tube through which the fluid passes. The vibration, though not completely circular, provides the rotating reference frame that gives rise to the Coriolis effect. While specific methods vary according to the design of the flow meter, sensors monitor and analyze changes in frequency, phase shift & amplitude of the vibrating flow tubes. The changes observed represent the mass flow rate and density of the fluid.

Features

● Measurement is not influenced by flow density, viscosity, temperature & pressure;
● Low requirement of straight pipe, because nothing inside holds back the flow;
● Low power dissipation; stable zero point; better accuracy;
● Meter is ARM system with 3 calculators to count density, temperature & mass flow rate; ● Transmitter is assembled by surface mounting technology with self-inspection function; ● ATEX approved(excluding Transmitter F210). Cert. No. TPS 18 ATEX 04516 001 X

Mass Flow Transmitter, Mass Flow Sensor, Mass Flow Metre, Coriolis Metre

Zhejiang Sealand Technology Co., Ltd. , https://www.sealandflowmeters.com