How to avoid the five regrets of floor installation
Unfortunately, the ground treatment is not flat It is prone to problems: If floors are laid on uneven ground, unevenness may occur behind the installed floor, and there is a large gap between the foot line and the floor. This not only affects the appearance, but also affects the service life of the floor lock, and even causes Floor noise. Friendly Tips: Correct prevention and construction methods: During the renovation, the ground should remain flat and the height difference within 2 meters should be less than 5 millimeters. Regret 2: The pipeline is not clear It is prone to problems: If the laying of pipelines in various rooms is not clear, it is easy to break the pipeline when installing the floor, and thus to re-maintain the pipelines, to waste time and increase trouble. Friendship Tip: Proper prevention and construction methods: Show the installation worker a pipe laying plan or make a mark at the pipeline before installing the floor. Regret 3: Height difference between floor and floor tiles It is prone to problems: Some customers' living room and room pavement will be floor tiles and floors, respectively, but floors and floor tiles will appear after the level difference, affecting the appearance. Friendship Tip: Proper prevention and construction methods: Ask the professional installer to know the thickness of the floor before paving the floor. Some ground leveling or keel laying is done according to the laying thickness. Regret 4: Door cover It is prone to problems: After the door-sleeve is installed, if the door seam is not reserved according to the height of the floor paving, the door-sleeve will need to be cut when paving the floor, which may cause the door cover to have burrs or paint collapse. Friendship Tip: Correct prevention and construction methods: When the door covers are installed, contact the floor company in advance and reserve the required height for the floor covering. Regret 5: The choice of geothermal floor It is prone to problems: In a geothermal environment, failure to lay the floor correctly or to use geothermal heat in the correct way may cause damage to the floor. Tips: Correct prevention and construction methods: First, choose the right geothermal floor, the most suitable is the multi-layer solid wood flooring, followed by the strengthening of the floor, solid wood is not suitable for geothermal environment. The second is that geothermal heat rises 5 degrees a day during initial use. Third, if the new type of geothermal pavement, geothermal companies to inform the floor pavement considerations. Del floor nature floor room paint decoration living room floor tiles
This product is suitable for all kinds of house-building concrete construction projects.
Engineering Achievements: Lenovo R&D Base; Cnooc Building; Financial Street Building
Surface Treatment: painted or as customer requirement
Application: House-building project
Type: Fair-faced concrete Formwork
Tolerance: GB or as customer requirements
Size: Customized
MOQ: 1 set
House Formwork,Fair-Faced Concrete Formwork,House Concrete Formwork,Formwork Of Concrete Anshan Lijian Engineering Group Co. LTD , https://www.lijianformwork.com